I. Features:
EDT horizontal torsion spring tester is an intelligent multifunctional measuring instrument designed and manufactured for testing and detecting various torsion springs. It can be used for torque testing of torsion springs, scroll springs and other elastic torsion parts of various shapes. It has the characteristics of simple operation, high accuracy, full functions, and easy to carry. Institutions and other industries.
Second, the main features:
1. High precision, high resolution, fast sampling speed, large screen display.
2, the upper and lower limits can be set, with sound and light alarm function
3. Three parameters display (torque force value, rotation angle, spring stiffness).
4. The three units N · m, kgf · cm, and Ibf · in are converted to each other.
5, real-time, peak, automatic peak three modes can be switched at will.
6, peak hold, automatic release function, release time freely set.
7. Automatic shutdown function without operation, time can be set freely.
8, large storage capacity, can save 99 sets of test data.
9. Automatic shutdown function without operation, time can be set freely.
10. Built-in mini printer (optional).
11. The USB interface communicates with the PC and can be connected to a computer for synchronous testing.
Specifications:
1. Measurement parameters:
parameter model |
Test torque |
Measuring range |
Minimum reading (N﹒mm) |
EDT-500A |
500 mN﹒ m |
5 ~ 500 (mN﹒m) |
0.01 mN﹒ m |
EDT-1000A |
1000 mN﹒ m |
10 ~ 1000 (mN﹒m) |
0.1 mN﹒ m |
EDT-2000A |
2000 mN﹒ m |
20 ~ 2000 (mN﹒m) |
0.1 mN﹒ m |
EDT-5000A |
5000 mN﹒ m |
50 ~ 5000 (mN﹒m) |
0.1 mN﹒ m |
EDT-1 |
1 N﹒ m |
0.01 ~ 1 (N﹒m) |
0.0001 N﹒ m |
EDT-2 |
2 N﹒ m |
0.02 ~ 2 (N﹒m) |
0.0001 N﹒ m |
EDT-5 |
5 N﹒ m |
0.05 ~ 5 (N﹒m) |
0.0001 N﹒ m |
EDT-10 |
10 N﹒ m |
0.1 ~ 10 (N﹒m) |
0.001 N﹒ m |
EDT-20 |
20 N﹒ m |
0.2 ~ 20 (N﹒m) |
0.001 N﹒ m |
EDT-30 |
30 N﹒ m |
0.3 ~ 30 (N﹒m) |
0.001 N﹒ m |
EDT-50 |
50 N﹒ m |
0.5 ~ 50 (N﹒m) |
0.001 N﹒ m |
2. Angle resolution: 0.1 °
3. Measuring angle range: 0 ~ ± 9999.9 °
4. Test piece rotation diameter: φ100mm
5. Test piece length: 150mm
6. Loading method: manual
7. Accuracy: ± 1%
8. Power supply: AC220V 50Hz
9. Dimensions: 710 × 320 × 290 (mm)
10. Weight: about 37.5Kg
Product schematic diagram
1.LCD display 2.Set parameter name bar 3.Function buttons
4.Special test head 5.USB interface 6.Power socket
Five: display panel
Six: Button description
1. ON / OFF key: can be used to turn on and off.
2. Angle clear key: In real-time measurement, press this key to correct the angle zero.
3. View key: Use this key to view the stored measurement data during the measurement interface.
4. Zero clear key: During real-time measurement, press this key to correct the torque zero. During the peak and automatic peak, press this key to clear the peak value and return to zero; when viewing the interface, press this key to clear the current stored measurement value, and long press this key to clear all stored measurement values. In the user setting interface, press this key to return to the previous interface without saving data.
5. Peak key: It is used to switch between three measurement modes: real-time, peak and automatic peak in the measurement interface. It has the function of moving up in the setting interface. In the view interface, press this key to view the previous data.
6. Save key: It is used to save the measured data in the measurement interface. It has the function of moving down in the setting interface.
In the view interface, press this key to view the next data.
7. Print key: In the measurement interface, press this key to print the stored measurement value (except those without print function). It has the function of moving left in the setting interface.
8. Unit key: Used to switch between N · m, kgf · cm, and Ib · in when measuring interface. It has the function of right shift in the setting interface.
9. Setting key: The user can enter the setting menu through this key on the measurement interface, and press this key to save the data when setting the data.
Seven: User operation instructions
1. Startup display
Startup display welcome and manufacturer information
Display product name, model and version information
2. User main interface display
3. User setting interface
Press the setting key once, as shown below:
Use the up or down arrow to select the setting item. When the setting item is selected to the user, press the setting key to enter the parameter setting interface.
4.Parameter setting interface
In the user setting interface, press the setting key to enter the parameter setting interface, which is displayed as follows:
Setting parameter description: (Taking the maximum torque value as an example)
Use the up and down keys to shift and modify the data. At this time, press the set key to confirm and save the set data (such as pressing the zero key to return without modifying the data). The set data cannot exceed the maximum load value.
(1) Maximum torque value: The user sets the torque upper limit value, which can be set freely as required. When the upper limit value is reached, the number above the parameter name \"torque upper limit value \" flashes, and the buzzer alarms. The upper limit is not higher than full scale.
(2) Minimum torque value: The user sets the torque lower limit value, which can be set freely as required. When the lower limit value is reached, the number above the parameter name \"torque lower limit value \" flashes. The lower limit cannot be higher than the set upper limit.
(3) Setting the minimum storage value: The user sets the minimum storage value according to the storage needs, and data less than this value will not be stored.
Eight, other function description
1. Description of printing function: print data through micro printer.
2. Communication: communicate with the host computer via USB. The communication protocol is MODBUS-RTU protocol.
3. Save data: Save the data during measurement by the save key.
4. View stored data: View the stored data through the View key.
5. Alarm description: When the measured value exceeds the upper limit, the upper limit indicator will be displayed, and the buzzer will also alarm; when the measured value is lower than the lower limit, the lower limit indicator will be displayed. When the measured value exceeds 120% of the maximum load, it may cause damage to the sensor. When \"Overload \" warning prompt appears, the machine will enter the automatic protection state, you must press the zero key or restart the machine. If you can't measure, please long press the set key, enter the password: up key, down key, and press the set key Restore factory settings interface, select Restore factory settings, and press the set key to restore (if unable to restore, please contact the manufacturer).
Nine, operating environment
1. Operating temperature: -10 ℃ ~ 40 ℃.
2. Operating humidity: ≤90% RH.
3. There is no vibration source and no corrosive environment around.
4. Minimum peak hold value setting: The user needs to set freely according to the peak value, and the automatic peak measurement needs to be set. Data smaller than this value is not saved by the peak value.
5. Maximum deformation angle setting: The user can set the maximum value of the angle, which can be set freely as required. When the upper limit value is reached, the number above the parameter name \"Angle Maximum \" blinks.
6. Minimum deformation angle setting: The minimum angle can be set by the user and can be set freely as required.
7. Automatic peak time setting: The user can freely set the time that the peak needs to be held in the state of automatic peak measurement from 1 second to 99 seconds.
8. Automatic shutdown time setting: In the non-operation state, the automatic shutdown time can be freely set from 1 minute to 99 minutes.
9. Gravity acceleration setting: The user can set the gravity acceleration value according to the location of the area. The default value of this machine is 9.794.
10. Restore the initial settings: Improper user operation or multiple changes to the data appears confusing. You can use this setting to restore the data from 1 to 9 to the factory state.
X. Operating steps
1. Under normal circumstances, plug in the power cord and turn on the power switch. After the display is stable, if the displayed data is not zero, press the \"Clear \" key to clear it to clear the torque value.
2. According to the test needs, press the moment unit conversion button to select the required unit.
3. Set up before testing, the specific steps are as parameter setting interface.
Twelve Torsion Spring Torque Test Procedures
1. According to the test requirements, select a suitable mandrel and install the mandrel on the mounting holes on both sides of the test head.
Then install the tested spring on the main test mandrel, and fix it at one end through the secondary mandrel.
2. Shake the handle to make the third mandrel contact the other end of the torsion spring, and the force value and angle will be cleared at the same time immediately after contact.
3. The torque value and angle value displayed on the LCD screen are zero.
4. According to the requirements of torsion spring measurement, rotate the measurement handle smoothly and uniformly, and the technical parameters of the torsion spring to be measured can be displayed.
5. Repeat the above operation to verify the technical parameters of the torsion spring.
Fourteen, matters needing attention, maintenance and repair
1. Don't test the torque by overload. Be sure to test the torque within the test range of the torque tester, otherwise it will damage the instrument and may cause danger.
2. Do not tap the LCD screen and place objects on the LCD screen.
3. Do not press the function keys with nails, sharp objects or pointed objects.
4. Do not use the torque tester in the place where water, oil or other liquids are splashed. Store the torque tester in
Shade, dry and free from vibration.
5. Do not loosen the fixing screws of the torque test head.
6. Do not use any power supply other than the rated voltage, otherwise it may cause electric shock or fire.
7. Please do not pull out or insert the plug with wet hands, otherwise it may cause electric shock.
8. Please use a soft cloth to clean the machine, immerse a dry cloth in water soaked with detergent, wring dry, and then remove dust and dirt. Do not use chemicals that emit easily, such as volatile oils, thinners, alcohol, etc.
9. Handle gently during use and handling.
10. Do not disassemble, repair or modify the machine yourself. These actions may cause permanent failure of the instrument.
11. If any trouble occurs, please contact the place of purchase or the company.
12. Within one month from the date of sale of this product, product quality problems occur under normal use and no damage to the appearance. The customer should bring the original sales invoice, valid warranty card and complete packaging to the original purchase place or the company will replace the same specifications Model products, the replacement products continue the warranty period and terms of the original product.
13. Within one year from the date of sale of this product, under normal use conditions, non-human faults are covered by the warranty (the user disassembles the machine or repairs at other service points by the company without warranty), and the customer has the original sales invoice and the valid warranty Contact the original place of purchase for a free one-year warranty.
14. The warranty terms of this product are only applicable to ANH series products sold in the Chinese market. For products that exceed the replacement period and warranty period, customers can inquire about the maintenance of the original place of purchase or contact the company, and the company will provide paid repairs. .
Other supporting instruments
equipment name |
model |
equipment name |
model |
Digital push-pull force meter |
HF |
Electric vertical machine |
AEV |
Analog push-pull force meter |
NK |
Electric single column vertical machine |
AEL |
Digital torque tester |
ANL |
Electric horizontal machine |
AEH |
Bottle cap torque tester |
ANL-P |
Spiral roll test machine |
ASC |
Pointer torque driver |
ANQ |
Manual horizontal test stand |
AMH |
High-speed impact torque tester |
AGN |
Vertical and horizontal test rack |
ASL |
Dynamic torque tester |
AND |
Hand pressure type tensile and compression test stand |
AST |
Torque Wrench Calibrator |
ANJ |
Spiral tension and compression test stand |
ALX |
Torsion spring testing machine |
ANH |
Dedicated testing machine for peeling force |
ABL |
Spring tension and compression testing machine |
ATH |
Ball pressure test device |
AQY |
Shore rubber hardness tester |
LX |
Motorized hydraulic tension and compression test stand |
ALR |
Shore hardness tester bracket |
LAC-J |
Button Tester |
ABQ |
Fruit hardness tester |
AGY |
Terminal tensile tester |
ADL |
Fruit hardness tester holder |
GYJ |
Rope tension meter |
ASZ |
Tonometer |
ATN |
Side tension tester |
HD |